Electronic Adjustable Circuit Breaker MCCB with LCD Display - China Suppliers & Factory Quality Assurance

,

The D&T CBRM5KD MCCB is a high-performance circuit breaker from a trusted China supplier, designed with an ultra-compact size and a high breaking capacity. It meets the IEC 60947-2 standards and holds DEKRA certification, ensuring verified safety and reliability for users.

,

Featuring a dual-cover design, the CBRM5KD provides live-part isolation, making accessory installation safe and straightforward.

,

Manufactured in our advanced factory, our production line utilizes automated screw fastening, precision laser marking, and fully automated testing systems. Every unit is subjected to 100% automated testing on critical parameters such as trip force, overtravel, contact gap, loop resistance, final contact pressure, power-frequency withstand voltage, and tripping characteristics, guaranteeing consistent and dependable operation.

,

    Product Model & Description

    Product Model & Description

    Four-Pole Product Codes

    • Type A: The N pole is not equipped with an overcurrent release and remains permanently connected; it does not open or close together with the other three poles.
    • Type B: The N pole is not equipped with an overcurrent release but opens and closes together with the other three poles (N pole closes first and opens last).

    Operating Environment

    Normal Operating Conditions

    Ambient Temperature Limit

    The upper limit of ambient air temperature shall not exceed +40°C, the lower limit shall not be lower than -5°C, and the average temperature within 24 hours shall not exceed +35°C. (Note: When the ambient air temperature exceeds +40°C or falls below -5°C, the use of the circuit breaker should be subject to agreement with the manufacturer.)

    Installation Altitude

    Installation altitude shall not exceed 2000 m.

    Atmospheric Humidity

    The relative humidity of the atmosphere shall not exceed 50% at the maximum ambient temperature of +40°C. Higher relative humidity is allowed at lower temperatures (e.g., 90% at 20°C), with consideration given to condensation that may occur due to temperature changes on the product surface.

    Normal Installation Conditions

    Installation Category

    Category Ⅲ for the main circuit, Category Ⅱ for the control and auxiliary circuits.

    Installation Orientation

    Generally installed vertically (upright), but horizontal (flat-mounted) installation is also permissible.

    Pollution Degree & Magnetic Field

    Pollution degree: Degree 3. The external magnetic field in the installation location shall not exceed 5 times the geomagnetic field in any direction.

    Trip Unit Types & Accessory Codes

    Trip Unit Types & Accessory Codes
    Trip Unit Types Details

    Main Technical Parameters

    Model

    CBRM5Kd-125i

    CBRM5Kd-160

    CBRM5Kd-250

    CBRM5Kd-400
    CBRM5Kd-630i

    CBRM5Kd-800

    Frame Size Current Inm(A)

    125

    160

    250

    400、630

    800

    Rated Current In(A)

    16、20、25、30、32、40、50、63、70、75、80、90、100、125

    16、20、25、30、32、40、50、63、70、75、80、90、100、125、140、150、160

    100、125、140、150、160、175、180、200、225、250

    225、250、280、300、315、350、400、500、550、630

    630、700、800

    Number of Poles

    3

    4

    3

    4

    3

    4

    3

    4

    3

    4

    Rated Insulation Voltage Ui(V)

    1000

    Rated Operation Voltage Ue(V)

    AC380、AC400、AC415

    AC380、AC400、AC415、AC660、AC690

    Rated Impulse Withstand Voltage Uimp(kV)

    8

    12

    Arc Distance(mm)

    50

    100

    Breaking Capacity Level

    L

    M

    H

    L

    M

    H

    L

    M

    H

    L

    M

    H

    L

    M

    H

    Ultimate Short-Circuit Breaking Capacity Icu(kA) AC380V/AC400V/AC415V

    10

    18

    25

    25

    36

    50

    36

    50

    70

    50

    70

    100

    50

    70

    100

    Service Short-Circuit Breaking Capacity Ics(kA) AC380V/AC400V/AC415V

    10

    18

    25

    25

    36

    50

    36

    50

    70

    50

    70

    100

    50

    70

    100

    Ultimate Short-Circuit Breaking Capacity Icu(kA) AC660V/AC690V

    -

    -

    -

    8

    10

    10

    10

    10

    10

    10

    15

    20

    15

    20

    20

    Service Short-Circuit Breaking Capacity Ics(kA) AC660V/AC690V

    -

    -

    -

    4

    5

    5

    5

    5

    5

    10

    15

    15

    13

    15

    15

    Operating Performance (operations)

    Energized

    1500

    1500

    1000

    1000

    500

    De-energized

    8500

    8500

    7000

    4000

    2500

    Total

    10000

    10000

    8000

    5000

    3000

    Protection Characteristics

    For Distribution Applications

    Rated Current (A) Thermal Trip Unit (Ambient Temp +40°C) Magnetic Trip Unit Operating Current (A)
    1.05In (Cold State) Non-Tripping Time (h) 1.3In (Hot State) Tripping Time (h)
    10 ≤ In ≤ 63 No Tripping Within 1 hour ≤ 1 10In ± 20%
    160 Frame, 16-32A: 400A ± 20%
    63 < In ≤ 800 No Tripping Within 2 hours ≤ 2

    For Motor Protection

    Rated Current (A) Thermal Trip Unit (Ambient Temp +40°C) Magnetic Trip Unit Operating Current (A)
    1.0In (Cold State) Non-Tripping Time (h) 1.2In (Hot State) Tripping Time (h) 1.5In (Hot State) Tripping Time (h) 7.2In (Cold State) Tripping Time (s) Trip Level
    10 ≤ In ≤ 25 No Tripping Within 2 hours ≤ 2 ≤ 2 min 0.5s < Tp ≤ 5s 5 12In ± 20%
    160 Frame, 16-32A: 400A ± 20%
    25 < In ≤ 250 ≤ 4 min 4s < Tp ≤ 10s 10
    250 < In ≤ 800 ≤ 8 min 6s < Tp ≤ 20s 20

    Circuit Breaker Classification

    • By Number of Poles: Three-Pole, Four-Pole
    • By Application: For Distribution, For Motor Protection
    • By Operating Method: Direct Handle Operation, Electric Operation (indicated by "p"), Rotary Handle Operation for Switchgear (indicated by "Z")

    Frequently Asked Questions

    What is the difference between Type A and Type B four-pole circuit breakers?

    For Type A, the N pole is not equipped with an overcurrent release, remains permanently connected, and does not open or close with the other three poles. For Type B, the N pole is also not equipped with an overcurrent release but opens and closes together with the other three poles (closing first and opening last).

    What are the ambient temperature limits for these circuit breakers?

    The normal operating ambient air temperature should be between -5°C and +40°C, with a 24-hour average temperature not exceeding +35°C. For operations outside this range, please consult the manufacturer.

    Can the circuit breakers be installed horizontally?

    Yes, while they are generally designed to be installed vertically (upright), horizontal (flat-mounted) installation is also permissible.

    What is the maximum installation altitude?

    The installation altitude for these circuit breakers should not exceed 2000 meters.

    What operating methods are available for the circuit breakers?

    They can be operated using three methods: Direct Handle Operation, Electric Operation (indicated by "p"), or Rotary Handle Operation for Switchgear (indicated by "Z").

    What is the rated insulation voltage (Ui) of the CBRM5Kd series?

    The rated insulation voltage (Ui) for this series of circuit breakers is 1000V.