China Suppliers Factory CBRM5EL Compact Automatic Reclosing Circuit Breaker with Residual Current Protection (MCCB)
Residual Current Protection (RCD) Circuit Breaker (Smart Reclosing)
Product Model and Meaning
Meets standards
The product meets the following standards.
GB/T14048.1-2012 Low voltage switchgear and control equipment Part 1: General principles;
GB/T14048.2-2008 Low-voltage switchgear and control equipment Part 2: Circuit breakers;
GB/T1770 1-2008 <Equipment circuit breakers>.
Main functions and features
- Adopt high-performance 32-bit ARM microprocessor, real-time signal processing and intelligent control; LCD Chinese display, user-friendly interface, easy operation;
- The residual current (leakage current) protection can be adjusted online, and has the function of reclosing;
- Real-time monitoring and tracking of the residual current of the line, automatic adjustment of the range, to ensure the operation rate and reliability of the product;
- Three-stage protection, long delay, short delay and instantaneous, using electronic trip, independent of power supply voltage;
- It has high breaking capacity and ensures the reliability of line short circuit protection. Overvoltage protection, undervoltage protection, phase loss protection;
- The residual current of the line, the three-phase power supply voltage and the load current are displayed in real time;
- Protective functions and parameters can be set and modified online.
- Trip types (residual current, lockout, overload, undervoltage, overvoltage, phase loss) are identified, displayed, and can be stored, queried, and deleted;
- The network has communication function, which can realize remote signal, remote measurement, remote control and remote adjustment.
- Plug-and-play lightning protection module (optional).
- Supports infrared communication (optional).
Key technical specifications
| Specifications and models | CERM5EL-125CY CBRM5EL-125CS |
CERM5EL-250CY CRRM5EL-250CS |
CBRM5EL-400CY CBRM5EL-400CS |
CBRM5EL-630CY CRRM5EL-630CS |
|
| Rated current of the shell frame class (A) | 125 | 250 | 400 | 630 | |
| Number of poles | 3P+N | 3P+N | 3P+N | 3P+N | |
| Rated working voltage Ue (V) | AC 400/50HZ | ||||
| Rated insulation voltage Ui(V) | 800 | 1000 | |||
| Rated impulse withstand voltage Uimp(V) | 8000 | ||||
| Flashover distance(mm) | ≠50 | ≠100 | |||
| Maximum short-circuit breaking capacity (lcu, kA) | 50 | 65 | 85 | ||
| Operating short-circuit breaking capacity (les, kA) | 35 | 42 | 65 | ||
| Rated residual short-circuit breaking capacity I△m (kA) | 12.5 | 16.25 | 21.25 | ||
| Rated short-time withstand current (LCW) in kA/s | 1.5 | 3 | 5 | 8 | |
| RCD trip characteristics | AC mould | ||||
| Rated residual operating current I△n (mA) | 50/100/200/300/400/500/600/800 MCU automatically tacks or manually sets any value |
100/200/300/400/500 600/800/1000 MCU automatic trucking or manual setting |
|||
| Remaining motion time characteristics | Delayed/non-delayed | ||||
| Delay-type limit non-drive time (s) | 0.06:21△n | ||||
| Break-time(s) | I△n≤≤0.5;21△n≤0.2:51△n≤0.15 | ||||
| Automatic reclosing time (s) | 20-60 | ||||
| Operation performance (times) | Set up an electric circuit | 1500 | 1000 | 1000 | |
| No power | 8500 | 7000 | 1000 | ||
| Total | 10000 | 8000 | 5000 | ||
| Overload and short-circuit characteristics | Three stage protection with electronic adjustment, See "Protection Characteristics" for details. | ||||
| Over-voltage protection value (V) | Set value (250~300)±5% | ||||
| Under-voltage protection value (V) | Set value (145-200)±5% | ||||
| Control delay time (ms) | ≤40ms | ||||
| Communication delay (ms) | ≤200ms | ||||
Protection feature description
◆Overload and long delay protection
Action value range
Table 1:Overload Long Delay Parameter Settings
| Parameter | Shroud current | Set value | Factory set value |
|---|---|---|---|
| Action set-point Irl | 125 | 50A、63A、80A、100A、125A | 125A |
| 250 | 100A、125A、140A、160A、180A、200A、225A、250A | 250A | |
| 400 | 160A、180A、200A、225A、250A、315A、350A、400A | 400A | |
| 630 | 250A、315A、350A、400A、500A、630A | 630A | |
| Delay time setting value tL | 3s,4s,6s,8s, 10s,12s,16s, 18s, OFF | 12s | |
◆Performance characteristic
Table 2: Protection Action Characteristics
| Ambient temperature | Current name | Set current multiplier | Appointed time |
|---|---|---|---|
| +40℃ | Conventional non tripping current | 1.051r1 | ≥2h |
| Conventional tripping current | 1.3Ir1 | <2h |
◆Time-delay characteristics
The overload protection is based on the inverse time characteristic.
The delay time is calculated as T=(6lrl/l) x L, with a tolerance of+10%.Here,T represents the action time, lrl is the long delay protection setting, i denotes the fault current, and L stands for the long delay time setting.
◆Short circuit short delay protection
Short delay protection prevents impedance short circuit in the power distribution sytem. and the trip delay is to achieve selective protection.Short-circuit short delay protection parameter settings.
Table 3: Short-Circuit Delay Parameter Setting
| Parameter setting | Set value | Factory set value |
|---|---|---|
| Short delay action current setting Ir2 | 2Irl,2.5lrl,3Irl,4lrl,5Ir1,6lIrl,7Irl,8lrl,10Irl,12lr | 6lr1 |
| Short delay time setting value ts | 10.1s,0.2s,0.3s,0.4s,0.6s,0.8s,1.0s,OFF | 0.4s |
Short-circuit short delay protection action characteristics
Table 4:Short Delay Action Characteristics of Short Circuit
| Characteristic | Fault current multiple | Trip characteristics | Delay error |
|---|---|---|---|
| No action feature | ≤0.85 Ir2 | Failure to actuate | / |
| Performance characteristic | >1.15 Ir2 | Deferred action | ±40ms |
◆Instant Protection
Set parameters for instantaneous short-circuit protection
Table 5:Instantaneous parameter setting
| Parameter setting | Set value | Factory set value |
|---|---|---|
| Instantaneous action current setting Ir3 | 4 Irl,6 Irl,7 Irl,8 Irl,9 Irl,10 Irl,11 Irl,12 Irl,13 Irl,14 Irl,OFF | 10 Ir1 |
Instantaneous short-circuit protection characteristics
Table 6:Instantaneous Motion Characteristics
| Characteristic | Current multiplier (1/r3) | Trip characteristics | Trip time |
|---|---|---|---|
| No action feature | ≤0.85 | Failure to actuate | ≥200ms |
| Performance characteristic | >1. 15 | Movement | <200ms |
◆Setting range for residual current protection characteristics
Table 7
| Parameter | Set value (125.250,400) | Set value (630) | Factory set value |
|---|---|---|---|
| Remaining motion current IΔn | 50,100,200,300,400500,600,800.automatic | 100,200,300,400,500,600,800.1000automatic | 500 |
◆Performance characteristic
Table 8: Protection Action Characteristics
| Parameter | Characteristic | |||
| Rated no-load current | 0.5IΔn | |||
| Rated operating current | ≥0.751Δn | |||
| Time-delay characteristics | 2IΔn Limit Time (Δt) | Break-time | ||
| IΔn | 2IΔn | 5IΔn | ||
| Non-delay | ≤0.3s | ≤0.15s | ≤0.04s | |
| 0.06 | ≥0.06s | ≤0.5s | ≤0.2s | ≤0.15s |
◆Auto mode
In automatic gear mode, the gear values and floating values are:
| Gauge reading (mA) | Floating value (mA) |
|---|---|
| 50 | 25 |
| 100 | 50 |
| 200 | 100 |
| 300 | 150 |
| 400 | 200 |
| 500 | 250 |
| 600 | 300 |
| 800 | 400 |
| 1000 | - |
When the residual current exceeds the floating threshold of a setting without reaching its activation level and remains stable for 60 seconds, the setting is raised by one level. This process continues until reaching the maximum setting. Conversely, when the residual current falls below the floating threshold of the next lower setting and remains stable for 120 seconds, the setting is lowered by one level. This sequence repeats until the minimum setting is reached. Taking the 'Auto 2' setting with an initial residual current of 100mA as an example: When the circuit breaker is energized, the setting automatically resets to 300mA. If the residual current increases above 150mA and remains stable for 60 seconds, the setting changes to 500mA. When the residual current decreases below 150mA and stays stable for 120 seconds, the setting adjusts to 200mA.
◆Autoreclose circuit breaker
When the residual current exceeds the set trip current threshold, the circuit breaker will trip. After 20-60 seconds, it can automatically reclose, though manual reclosing is unrestricted. If the fault current disappears within 5 seconds after reclosing, the operation is successful and the breaker resumes normal operation. If the fault persists, the breaker will trip again and remain locked, preventing automatic reclosing. In such cases, manual reclosing must be performed.
◆Over-voltage protection
When the line phase voltage exceeds the overvoltage protection setting, the circuit breaker trips. Once the voltage returns to normal, the circuit breaker automatically recloses and resumes operation. The overvoltage protection setting ranges from 250V to 300V, with a factory default of 275V. Users can adjust or disable the protection as needed.
◆Undervoltage protection
When the phase voltage falls below the undervoltage protection setting, the circuit breaker trips. Once the voltage returns to normal, the breaker automatically recloses. The undervoltage protection range is 145V to 200V, with a factory default of 145V. Users can adjust or disable the protection as needed.
◆Phase loss protection function
When a phase is missing at the power supply end of the line, the circuit breaker protection trips. When the line is restored to normal voltage, the circuit breaker can be automatically closed and put into operation.
Outline Overall and Installing Dimensions
characteristic curve
◆Linked protection function
The Linkage lnterface Can Be Used to Coordinate With Other Fire Fighting Equipment for Protection as Follows.
| IN input settings | Function declaration | Priority | Delay time | |
|---|---|---|---|---|
| Input control | IN1 is short-circuited to DCOM | Circuit breaker closed | Low | ≤40ms |
| IN3 is short-circuited to DCOM | Trip the circuit breaker | Gao | ≤40ms | |
Note: Prolonged short-circuiting will keep the circuit breaker in the open state.

CBRM5EL Automatic Reclosing MCCB
CBRM3EL Remote Reclosing MCCB
CBRM5E Intelligent MCCB
CBRM5EKd Electronic MCCB
CBRM5Kd Compact MCCB
CBRM5K Lockable MCCB
CBRM5EN Primary-secondary Separated MCCB
CBRECB Meter Remote Control MCCB
CBRB7BL Type B Smart RCBO
CBRB7 Compact MCB
CBRB7-AP PV Grid-connected MCB
CBRW3 4000A ACB
CBRW3 2500A ACB
CBRW3 1600A ACB