China Suppliers Factory CBRM5EKd Electronic Adjustable Circuit Breaker MCCB with LCD Display - High Breaking Capacity

,

D&T CBRM5KD MCCB is a highly compact circuit breaker with an exceptional breaking capacity, designed in accordance with IEC 60947-2 standards. Our product is certified by DEKRA, guaranteeing its safety and performance features for users seeking reliable solutions from reputable China suppliers.

,

Featuring a dual-cover design, the CBRM5KD ensures effective live-part isolation, making the installation of accessories safe and straightforward.

,

Manufactured in our state-of-the-art factory, we utilize advanced automation technologies, including automatic screw fastening, precision laser marking, and comprehensive automated testing systems. Each unit is subjected to rigorous 100% automated testing for trip force, overtravel, contact gap, loop resistance, final contact pressure, power-frequency withstand voltage, and tripping characteristics, ensuring consistent reliability and performance typical of high-quality products from China.

,

    Product Model & Description

    Product Model & Description
    Four-Pole Product Codes
    • Type A: The N pole is not equipped with an overcurrent release and remains permanently connected; it does not open or close together with the other three poles.
    • Type B: The N pole is not equipped with an overcurrent release but opens and closes together with the other three poles (N pole closes first and opens last).

    Operating Environment

    Normal Operating Conditions

    ◆ The upper limit of ambient air temperature shall not exceed +40°C, the lower limit shall not be lower than -5°C, and the average temperature within 24 hours shall not exceed +35°C. Note: When the ambient air temperature exceeds +40°C or falls below -5°C, the use of the circuit breaker should be subject to agreement with the manufacturer.

    ◆ Installation altitude shall not exceed 2000 m.

    ◆ The relative humidity of the atmosphere shall not exceed 50% at the maximum ambient temperature of +40°C. Higher relative humidity is allowed at lower temperatures (e.g., 90% at 20°C), with consideration given to condensation that may occur due to temperature changes on the product surface.

    Normal Installation Conditions

    ◆ Installation category: Category Ⅲ for the main circuit, Category Ⅱ for the control and auxiliary circuits.

    ◆ Installation orientation: Generally installed vertically (upright), but horizontal (flat-mounted) installation is also permissible.

    ◆ Pollution degree: Degree 3.

    ◆ External magnetic field: The external magnetic field in the installation location shall not exceed 5 times the geomagnetic field in any direction.

    Trip Unit Types & Accessory Codes

    Trip Unit Types & Accessory Codes
    Trip Unit Types & Accessory Codes Details

    Main Technical Parameters

    Model

    CBRM5Kd-125i

    CBRM5Kd-160

    CBRM5Kd-250

    CBRM5Kd-400
    CBRM5Kd-630i

    CBRM5Kd-800

    Frame Size Current Inm(A)

    125

    160

    250

    400、630

    800

    Rated Current In(A)

    16、20、25、30、32、40、50、63、70、75、80、90、100、125

    16、20、25、30、32、40、50、63、70、75、80、90、100、125、140、150、160

    100、125、140、150、160、175、180、200、225、250

    225、250、280、300、315、350、400、500、550、630

    630、700、800

    Number of Poles

    3

    4

    3

    4

    3

    4

    3

    4

    3

    4

    Rated Insulation Voltage Ui(V)

    1000

    Rated Operation Voltage Ue(V)

    AC380、AC400、AC415

    AC380、AC400、AC415、AC660、AC690

    Rated Impulse Withstand Voltage Uimp(kV)

    8

    12

    Arc Distance(mm)

    50

    100

    Breaking Capacity Level

    L

    M

    H

    L

    M

    H

    L

    M

    H

    L

    M

    H

    L

    M

    H

    Ultimate Short-Circuit Breaking Capacity Icu(kA) AC380V/AC400V/AC415V

    10

    18

    25

    25

    36

    50

    36

    50

    70

    50

    70

    100

    50

    70

    100

    Service Short-Circuit Breaking Capacity Ics(kA) AC380V/AC400V/AC415V

    10

    18

    25

    25

    36

    50

    36

    50

    70

    50

    70

    100

    50

    70

    100

    Ultimate Short-Circuit Breaking Capacity Icu(kA) AC660V/AC690V

    -

    -

    -

    8

    10

    10

    10

    10

    10

    10

    15

    20

    15

    20

    20

    Service Short-Circuit Breaking Capacity Ics(kA) AC660V/AC690V

    -

    -

    -

    4

    5

    5

    5

    5

    5

    10

    15

    15

    13

    15

    15

    Operating Performance (operations)

    Energized

    1500

    1500

    1000

    1000

    500

    De-energized

    8500

    8500

    7000

    4000

    2500

    Total

    10000

    10000

    8000

    5000

    3000

    Protection Characteristics

    For Distribution Applications

    Rated Current (A)

    Thermal Trip Unit (Ambient Temp +40)

    Magnetic Trip Unit Operating Current (A)

    1.05In(Cold State) Non-Tripping Time (h)

    1.3In (Hot State) Tripping Time (h)

    10≤In≤63

    No Tripping Within 1 hour

    ≤1

    10In±20%
    160 Frame,16-32A:400A±20%

    63<In≤800

    No Tripping Within 2 hours

    ≤2

    For Motor Protection

    Rated Current (A)

    Thermal Trip Unit (Ambient Temp +40)

    Magnetic Trip Unit Operating Current (A)

    1.0In(Cold State)Non-Tripping Time (h)

    1.2In(Hot State) Tripping Time (h)

    1.5In(Hot State) Tripping Time (h)

    7.2In(Cold State)Tripping Time (h)

    Trip Level

    10≤In≤25

    No Tripping Within 2 hours

    ≤2

    ≤2min

    0.5s<Tp≤5s

    5

    12In±20%
    160 Frame,16-32A:400A ±20%

    25<In≤250

    ≤4min

    4s<Tp≤10s

    10

    250<In≤800

    ≤8min

    6s<Tp≤20s

    20

    Circuit Breaker Classification

    • By Number of Poles: Three-Pole, Four-Pole
    • By Application: For Distribution, For Motor Protection
    • By Operating Method: Direct Handle Operation, Electric Operation (indicated by "p"), Rotary Handle Operation for Switchgear (indicated by "Z")

    Frequently Asked Questions (FAQ)

    Q1: What are the differences between Type A and Type B four-pole circuit breakers?

    A1: For Type A, the N pole is not equipped with an overcurrent release, remains permanently connected, and does not open or close together with the other three poles. For Type B, the N pole is also not equipped with an overcurrent release, but it opens and closes together with the other three poles (closing first and opening last).

    Q2: What is the maximum installation altitude allowed for these circuit breakers?

    A2: The installation altitude for these circuit breakers must not exceed 2000 meters.

    Q3: Under what temperature conditions can this circuit breaker operate normally?

    A3: The normal ambient air temperature should be within the range of -5°C to +40°C, and the average temperature over a 24-hour period must not exceed +35°C. For temperatures outside this range, usage must be agreed upon with the manufacturer.

    Q4: Can the circuit breaker be installed horizontally?

    A4: Yes. Although the circuit breaker is generally designed to be installed vertically (upright), horizontal (flat-mounted) installation is also permissible.

    Q5: What do the letters "p" and "Z" stand for in the operating methods?

    A5: The letter "p" indicates Electric Operation, and the letter "Z" indicates Rotary Handle Operation for switchgear.

    Q6: What is the rated insulation voltage (Ui) of these circuit breakers?

    A6: The rated insulation voltage (Ui) for these circuit breaker models is 1000V.