China CBRM5Kd Compact MCCB Molded Case Circuit Breaker - Reliable Suppliers & Factory for High Performance

The D&T CBRM5KD MCCB is a compact circuit breaker featuring high breaking capacity, designed to meet IEC 60947-2 standards. As a certified product by DEKRA, it guarantees superior safety and performance. This model includes a dual-cover design that provides effective isolation of live parts, facilitating the safe and straightforward installation of accessories, Manufactured in our advanced factory in China, the CBRM5KD circuit breaker benefits from state-of-the-art production techniques. Our facility is equipped with automatic screw fastening, precision laser marking, and fully automated testing systems. Each unit undergoes rigorous 100% automated testing that includes assessments of trip force, overtravel, contact gap, loop resistance, final contact pressure, power-frequency withstand voltage, and tripping characteristics. This comprehensive testing process ensures that our products deliver consistent and reliable performance, making us a trusted supplier in the circuit breaker industry

    Product Model & Description

    Product Model & Description

    Four-Pole Product Codes

    • Type A: The N pole is not equipped with an overcurrent release and remains permanently connected; it does not open or close together with the other three poles.
    • Type B: The N pole is not equipped with an overcurrent release but opens and closes together with the other three poles (N pole closes first and opens last).

    Operating Environment

    Normal Operating Conditions

    • The upper limit of ambient air temperature shall not exceed +40°C, the lower limit shall not be lower than -5°C, and the average temperature within 24 hours shall not exceed +35°C. (Note: When ambient temperature exceeds +40°C or falls below -5°C, use should be subject to agreement with the manufacturer.)
    • Installation altitude shall not exceed 2000 m.
    • The relative humidity of the atmosphere shall not exceed 50% at the maximum ambient temperature of +40°C. Higher relative humidity is allowed at lower temperatures (e.g., 90% at 20°C), considering condensation that may occur due to temperature changes on the product surface.

    Normal Installation Conditions

    • Installation category: Category Ⅲ for the main circuit, Category Ⅱ for the control and auxiliary circuits.
    • Installation orientation: Generally installed vertically (upright), but horizontal (flat-mounted) installation is also permissible.
    • Pollution degree: Degree 3.
    • External magnetic field: Shall not exceed 5 times the geomagnetic field in any direction at the installation location.

    Trip Unit Types & Accessory Codes

    Trip Unit Types & Accessory Codes
    Trip Unit Types & Accessory Codes Details

    Main Technical Parameters

    Model CBRM5Kd-125i CBRM5Kd-160 CBRM5Kd-250 CBRM5Kd-400 / CBRM5Kd-630i CBRM5Kd-800
    Frame Size Current Inm(A) 125 160 250 400, 630 800
    Rated Current In(A) 16, 20, 25, 30, 32, 40, 50, 63, 70, 75, 80, 90, 100, 125 16, 20, 25, 30, 32, 40, 50, 63, 70, 75, 80, 90, 100, 125, 140, 150, 160 100, 125, 140, 150, 160, 175, 180, 200, 225, 250 225, 250, 280, 300, 315, 350, 400, 500, 550, 630 630, 700, 800
    Number of Poles 3 4 3 4 3 4 3 4 3 4
    Rated Insulation Voltage Ui(V) 1000
    Rated Operation Voltage Ue(V) AC380, AC400, AC415 AC380, AC400, AC415, AC660, AC690
    Rated Impulse Withstand Voltage Uimp(kV) 8 12
    Arc Distance(mm) 50 100
    Breaking Capacity Level L M H L M H L M H L M H L M H
    Ultimate Short-Circuit Breaking Capacity Icu(kA) AC380V/AC400V/AC415V 10 18 25 25 36 50 36 50 70 50 70 100 50 70 100
    Service Short-Circuit Breaking Capacity Ics(kA) AC380V/AC400V/AC415V 10 18 25 25 36 50 36 50 70 50 70 100 50 70 100
    Ultimate Short-Circuit Breaking Capacity Icu(kA) AC660V/AC690V - - - 8 10 10 10 10 10 10 15 20 15 20 20
    Service Short-Circuit Breaking Capacity Ics(kA) AC660V/AC690V - - - 4 5 5 5 5 5 10 15 15 13 15 15
    Operating Performance (operations) Energized 1500 1500 1000 1000 500
    De-energized 8500 8500 7000 4000 2500
    Total 10000 10000 8000 5000 3000

    Protection Characteristics

    For Distribution Applications

    Rated Current (A) Thermal Trip Unit (Ambient Temp +40°C) Magnetic Trip Unit Operating Current (A)
    1.05In (Cold State) Non-Tripping Time (h) 1.3In (Hot State) Tripping Time (h)
    10 ≤ In ≤ 63 No Tripping Within 1 hour ≤ 1 10In ± 20%
    160 Frame, 16-32A: 400A ± 20%
    63 < In ≤ 800 No Tripping Within 2 hours ≤ 2

    For Motor Protection

    Rated Current (A) Thermal Trip Unit (Ambient Temp +40°C) Magnetic Trip Unit Operating Current (A)
    1.0In (Cold State) Non-Tripping Time (h) 1.2In (Hot State) Tripping Time (h) 1.5In (Hot State) Tripping Time (h) 7.2In (Cold State) Tripping Time (h) Trip Level
    10 ≤ In ≤ 25 No Tripping Within 2 hours ≤ 2 ≤ 2 min 0.5s < Tp ≤ 5s 5 12In ± 20%
    160 Frame, 16-32A: 400A ± 20%
    25 < In ≤ 250 ≤ 4 min 4s < Tp ≤ 10s 10
    250 < In ≤ 800 ≤ 8 min 6s < Tp ≤ 20s 20

    Circuit Breaker Classification

    • By Number of Poles: Three-Pole, Four-Pole
    • By Application: For Distribution, For Motor Protection
    • By Operating Method: Direct Handle Operation, Electric Operation (indicated by "p"), Rotary Handle Operation for Switchgear (indicated by "Z")

    Frequently Asked Questions (FAQ)

    What is the difference between Type A and Type B four-pole circuit breakers?
    In Type A, the N pole is permanently connected, lacks an overcurrent release, and does not open or close with the other three poles. In Type B, the N pole also lacks an overcurrent release but opens and closes synchronously with the other three poles (closing first and opening last).
    What are the standard ambient temperature limits for normal operation?
    The ambient air temperature must remain between -5°C and +40°C, and the average temperature over a 24-hour period should not exceed +35°C. For operations outside this range, please consult the manufacturer.
    What is the maximum installation altitude for these circuit breakers?
    The circuit breakers are rated for normal installation and operation at altitudes up to 2000 meters above sea level.
    Can the circuit breakers be mounted horizontally?
    Yes. While vertical (upright) installation is the standard orientation, horizontal (flat-mounted) installation is also fully permissible.
    What do the letters "p" and "Z" represent in the operating methods?
    These letters indicate specific accessory operating mechanisms: "p" represents electric operation, and "Z" represents a rotary handle operating mechanism designed for switchgear.